Owner's Operation & Safety Manual
REMOTE PUMPS
Models FR713, 303, 313
Model 303 and 313
OUTSTANDING FEATURES
Up to 18 GPM / 60 LPM
UL & C-UL Listed
1/3 HP 115 VAC-60Hz motor,
optional 220/240 VAC-50/60Hz
Thermal overload protector
Integral check valve
Built-in bypass valve
Anti-siphon device
OUTSTANDING FEATURES
Up to 30 GPM / 114 LPM
UL & C-UL Listed
3/4 HP 115/230 VAC-60Hz motor
(313). For diesel applications. Not
recommended for gasoline.
1/2 HP 115/230 VAC-60Hz motor
(303). For gasoline and diesel
applications.
Thermal overload protector
Integral check valve
Built-in bypass valve
Anti-siphon device
Model FR713
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - REMOTE PUMPS

Owner's Operation & Safety ManualREMOTE PUMPSModels FR713, 303, 313Model 303 and 313OUTSTANDING FEATURESUp to 18 GPM / 60 LPMUL & C-UL

Strany 2 - SAFETY INSTRUCTIONS

Dear Fill-Rite Customer,Congratulations on your purchase of a Fill-Rite RemotePump. We at Fill-Rite have built our worldwide reputation bydesigning t

Strany 3

Model FR713Full 1/3 HP, 220/240 VAC, 50/60Hz motorPumps are furnished with factory installed anti-siphon devicesand must be installed in accordance w

Strany 4

051015202530024681012141618202224262830324FR713 FLOW CURVE*Flow in GPMDischarge Presssure (PSI)05101520250 2 4 6 8 10 12 14 16 18 20 22AXBXFlow in GPM

Strany 5 - FR713 PUMP PARTS LIST

5NEW OLDITM PART PART PARTNO. NO.  NO. * NO. DESCRIPTION QTYFR713 PUMP PARTS LIST700KTF2659 700B Repair Parts Kit (Includes items4, 7, 8, 9, 13, 14,

Strany 6 - 303 AND 313 PUMP PARTS LIST

6303 AND 313 PUMP PARTS LIST300KTF7794 Repair Kit (Includes items 3, 5, 8, 9, 12, and13, 18, 22, 24 and F2687 Seal Kit)NEW OLDITM. PART PART PARTNO. N

Strany 7 - TROUBLESHOOTING GUIDE

7Pump wont prime Suction line problem Check for leaks in suction line.Bypass valve open Remove and inspect valve.Vanes sticking Check vanes and

Strany 8 - F1130 REV. 3

Fill-Rite: A WorldwideReputation for Reliability.For over 40 years, people all over the world who haveneeded tough, dependable pumps have insisted on